2 10, 2018

Lakeland Engineering Equipment Company and Acrotech, Inc. Automate “Most Sophisticated Roll Bending Machine”

2018-11-19T17:06:08+00:00October 2nd, 2018|Informational, News|

OVERVIEW Acrotech, Inc. came to Lakeland Engineering Equipment Company in search of specific electrical components and automation expertise for a custom roll bending machine Acrotech was building for a new OEM customer. The machine needed to be automated to meet the customer’s specific requirements and goals, including a higher-level of machine operator safety and material rolling in one continuous pass. Having bought from Lakeland before and knowing the type of service, expertise, and resources that [...]

8 09, 2018

Designing Four NEC Class 2 Branch Circuits with One Power Supply

2018-11-21T20:04:26+00:00September 8th, 2018|Informational, New Products|

Simple and cost effective way to design four NEC Class 2 branch circuits by using just one power supply PULS recently released an educational whitepaper regarding NEC Codes and PISA – a new and innovative concept for current distribution and protection of branch circuits. PISA is a universal tool for most applications. With the PISA11.CLASS2 module, several individual NEC Class 2 power supplies can be replaced by one large and more cost-effective power supply. The [...]

20 07, 2018

Connecting Your Plant Floor to Prepare for IIoT

2018-11-19T17:19:09+00:00July 20th, 2018|Informational|

How Protocol Conversion can Connect Your Plant Floor to Prepare for IIoT Have you considered implementing a solution that would allow you to become more intelligent about your manufacturing plant, machines, and overall processes? The buzz around Industrial IoT is growing immensely as more and more industries realize the benefits connectivity can provide. These benefits include the ability to minimize downtime, increases efficiency, save costs, and more. How do I Prepare My Plant or Manufacturing [...]

17 07, 2018

Automatically Verify Absence of Voltage with 6 Steps in 10 Seconds

2018-07-17T20:14:35+00:00July 17th, 2018|Informational, New Products|

Panduit VeriSafe™ Absence of Voltage Tester A voltage verification test is required when servicing electrical equipment to validate the absence of voltage. This is mandated by NFPA 70E, requiring workers to verify that equipment is in an electrically safe state, including the absence of voltage test. There are two common tools to measure absence of voltage – portable and permanent testers. With portable absence of voltage testers, the electrical worker performs the steps manually. These [...]

11 06, 2018

How to Reduce Energy Costs with VFDs and Power Factor Correction

2018-11-21T20:14:43+00:00June 11th, 2018|Informational|

VFD Energy Cost Savings  Taking steps to reduce the amount of energy your business consumes provides year over year cost savings. There are multiple ways to reduce energy consumption and cost. Utility companies including Xcel Energy are also rewarding users for improving their energy usage through a rebate system. One way to save energy is by adding variable frequency drives (VFD) to your systems. Variable frequency drives are often used to provide energy savings – [...]

2 03, 2018

Yaskawa Changes the Game with the U1000 Matrix Drive

2018-11-21T12:33:30+00:00March 2nd, 2018|Informational, New Products|

Matrix Designed VFDs The Yaskawa U1000 Matrix Drive is a relatively new VFD that was designed as a Clean Power VFD and solution for regenerative power applications. The drive provides low harmonics, with less than 5% iTHD at the input terminals of the VFD and is ideal for a host of industrial applications. The design of the drive obviates the DC bus by using nine bi-directional IGBTs (insulated-gate bipolar transistors) in a matrix arrangement to generate the [...]

23 01, 2018

Optimize Your Control Panel: How to Apply UL 489 and UL 1077 Devices

2022-03-21T20:01:19+00:00January 23rd, 2018|Informational, Safety|

Understanding How to Apply UL 489 and UL 1077 Devices Do you know the differences between UL 489 and UL 1077? The key to understanding UL 1077 supplementary protection and UL 489 branch protection requirements is to first understand how to identify the products, the applications they can be used for and importance of selecting the correct device in compliance with UL standards. While both types of protection are useful and have similar purposes, each [...]

27 11, 2017

Are you in Compliance with NEC Surge Protection Code 670.6?

2017-11-27T17:49:57+00:00November 27th, 2017|Informational, Safety|

Lakeland Engineering Equipment Company is committed to keeping our customers up to date on the latest safety and compliance information. The NFPA 70, or National Electrical Code (NEC), implemented a new code that specifically affects the industrial industry. The NEC Code 670.6 states that, “industrial machinery with safety interlock circuits shall have surge protection installed.” The new surge protection code requirements require all safety interlocks on industrial machinery to have surge protection installed. This enhances safety and reliability. [...]

13 09, 2017

How many Switches & Valves are in Your Facility?

2017-09-13T19:55:46+00:00September 13th, 2017|Informational, Services|

Lakeland Engineering Equipment Co. is proud to offer our customers the complete line of ASCO solenoid valves and Honeywell MicroSwitch products to keep your operations running smoothly. Did you know that Lakeland Engineering can provide a complete survey on the types and quantities of valves and switches in your facility? The valve and switch survey information allows you to streamline ordering processes and consolidate suppliers. Lakeland is ready to inform and adjust our inventory to [...]